THIRD DECADE  
necessary to enlarge and reorganize dynamo test; by the end of 1920 two new pits had been provided, one for turbo-generators and one for rotary converters and induction motors, and plant rated at 25,000 kVA could be tested. Further world's records for their speeds were set up in 1925 by generators rated at 43,750 kVA 1500 r.p.m. and 15,625 kVA 3600 r.p.m. for Japan, and in 1926 by a 38,500-kVA 3000-r.p.m. machine for Russia. A 62,500-kVA 1500-r.p.m. turbo-generator built for Portishead in 1928 was the largest that had been produced in any British factory.

These rapid developments required testing accommodation in which the rotors could be run at over-speed, and in view of their size a special test house was built in 1926. It was made of concrete lined with timber and sandbags almost enough to resist a bomb explosion, and the motor and gear box driving the rotor were placed outside the building. Overspeed tests are controlled by one man from a safe distance.

One of the most important technical developments was closed circuit ventilation. The air filters used on the early machines gave serious trouble, and in 1920 the Company's engineers decided to adopt a closed circuit system, in which the same air was used continuously and passed over water tube coolers. This system with subsequent improvements is still the standard method of ventilating large turbogenerators and similar machines.

Improvements in generator construction concerned the transposing of parallel conductor strips in the stator windings to reduce eddy currents, for which a method still in use was patented by J. A. Kuyser in 1920, and also the supporting and construction of rotor coil-retaining rings. The rings became more liable to move with the increasing length and speed of rotors, and trouble from the consequent damage to the insulation was cured in 1922 by the adoption of a sleeve-supported retaining ring. The use of non-magnetic steel for the retaining rings started in 1928 and had the effect of reducing the stray losses and also the intensity of stray magnetic fields, which caused local overheating at the ends of the stators.

For turbo-generator stators the Company introduced in 1924 the practice of bakelizing together the parallel straps of the slot conductors in order to provide a solid foundation on which to wrap the main insulation, thus avoiding insulation breakdown owing to movement Of the individual copper straps. Soon afterwards silver soldering by electric brazing was substituted for the soft soldering in general use on stator winding joints.

A three-part construction for turbo-generator rotors was adopted in 1927 to replace solid steel forgings, which were unobtainable in the sizes required for the largest 1500-r.p.m. machines. In the M-V design a central cylinder and two shaft ends were held together by links of high tensile steel, shrunk into slots at each end of the rotor; by measuring the length of each link before and after shrinking, thenstresses are accurately known. This construction has been used on generators totalling over 1,000,000 kVA in capacity.